Pay attention to the following 8 points when the magnetic pump is running:
1. Idling is strictly prohibited.
2. It is strictly prohibited to evacuate the medium.
3. When the outlet valve is closed, the continuous operation time of the pump shall not exceed 2 minutes to prevent the magnetic actuator from overheating and failing.
4. The magnetic torque cannot be designed too small.
5. It should be operated under specified temperature conditions, and the medium temperature is strictly prohibited from exceeding the standard. A platinum resistance temperature sensor can be installed on the outer surface of the magnetic pump isolation sleeve to detect the temperature rise in the annulus area, so as to alarm or shut down when the temperature exceeds the limit.
6. Ferromagnetic impurities and particles are not allowed to enter the stainless steel magnetic pump drive and bearing friction pair.
7. After transporting the medium that is easy to crystallize or precipitate, flush it in time (pour clean water into the pump cavity after stopping the pump, and drain it after 1 min of operation) to ensure the service life of the sliding bearing.
8. When the magnetic pump conveys the medium containing solid particles, it should be filtered at the inlet of the pump flow pipe.