Notes on magnetic pump filling machine
1. Check the AC power supply with 220 (± 5%) frequency and 50 Hz / 60 Hz (± 5%) power supply voltage, and correctly use the custom fuse. The power line must be pulled out before installing the fuse.
2 to avoid personal injury, please use the AC power socket on the ground. The power plug should be well touched. Otherwise, it is easy to damage the filling machine
3. The filling machine should be placed in a dry and ventilated place with less dust, and the distance between the filling machine and the wall or other objects should be greater than 20cm to ensure the normal ventilation
4. Check valve must be vertical downward, otherwise accuracy will be affected.
5. The filling head must be vertically downward, otherwise there will be dripping.
6. The bend angle of the pipeline should not be small, and it will affect the flow and accuracy.
7. The liquid level difference of raw material barrel should not be too large, otherwise the accuracy will be affected
8. Volatile liquids should be used in a circulating air environment